Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What Should I Know about Metering, Switchgear and Panels?

Answer Posted / sakthivel

metering
meter is a electrical apparatus it measure the
electrical parameter just like votage ,current energy etc..
switchgear
switchgear is a main importent electrical power control
switch it working depents on voltage, current sence
apparatus
panels
panels are electrical meters and switch gear fixing
coboard with use electrical rule.

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can XLPE/SWB/PVC (P3) 7C X 2.5mm2 be replaced by Can XLPE/SWB/PVC (P2) 7C X 2.5mm2??? P3 vs P2

1847


why moisture formation found in XLPE Armoured cable outer sheath

1791


1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.

2012


Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?

1893


Difference between a pilot wire and a normal conductor?

2034


Define stepper motor. What is the use of stepper motor?

1195


what is the meaning of WYE and DELTA in Electric meter?

3806


How many types oil using in transformer ? How many letars using in transformer..?

2081


A well system is when , no. of bus bar is less or more. Tell me the concept of it.

1899


any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?

2262


why we permissive overreach in distance protection.where it is applicable to use in long r short lines

2740


WHAT IS THE FUNCTION OF SHORT CIRCUIT MAINTENANCE CT

2429


An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.

7665


how did the testing of protection relays done through current injection

2060


what is the effect of higher value of GD???

1766