Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

p=hdg,please explain these parameters?

Answer Posted / ashish

p = pressure
h = height of tank
d = density of liquid
g = acceleration due to gravity

Is This Answer Correct ?    162 Yes 17 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?

1839


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1384


How do you identify an orifice in the pipeline?

1233


What is hp & mp seperator .& what is its working principle ?

2615


hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747

1983


Why do we floating DC in DC system.

2881


What are different types of valves?

1297


how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

2669


What is frequency factor in massflow meter? When using frequency output?

1838


sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers

2312


What is the cascade control

1399


The Design Calculation of Level Transmitter For Different Structure open & Closed Vessel, Eg. Diff. Level Tx., Capacitance For Continous Operation

2837


selection of the zener barrier for the hazardeous area zone 0

2241


How to interfacing microcontroller with a DC motor

2031


i have steam drum height 1000mm. and i want to placed the transmitter below the tap.how i calculate.

2062