WHAT IS THE DG OIL SPECIFICATIONS AND WHAT IS THE
DIFFERENCE BETWEEN THE DG OIL AND TRANSFORMER OIL
Answer Posted / shiva reddy
DG lube oil Specification is 15W/40
Difference between DG oil and Transformer oil is
DG oil is used for lubricating purpose because in DG Engine
lot of rotating parts are there,
Transormer oil Specification is 40KV and it is mineral oil
we are using oil in transformer for insulating and cooling
purpose
Is This Answer Correct ? | 18 Yes | 3 No |
Post New Answer View All Answers
What is a surge supressor why its is used in synchronous generators
my name is venkat .i have good percentage in my academics(ssc 86, intermediate 83 b.tech 73) my question 1..after completion of my ssc i joined in bpc but i didnt got rank in emcet so i completed MPC in one year compartmentally ..so here what am expect question from this background?
what is meant by the phrase 'static load' in case of shorting in a generator excitation system?
a starter used for squirrel cage induction motor?
What is the unit of magnetic flux density?
What is the difference between Delta & Wye windings?
A well system is when , no. of bus bar is less or more. Tell me the concept of it.
What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?
In TNC switch, is there any 1NO+1NC block ? and if we move over closing position, is ther any affect on trip position or vice versa?
Air refrigeration cycle works on the
Actually I have a doubt on neutral and earth.we use Ac power without taking neutral by connecting to earth,but at that time does it affects on efficiency of any electrical components or no? If yes how?
what are the tests comes under the type test, what tests comes under routine tests.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
What is the function of a neutral reactor.
what is meant by skew width in machines?