Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE DG OIL SPECIFICATIONS AND WHAT IS THE
DIFFERENCE BETWEEN THE DG OIL AND TRANSFORMER OIL

Answer Posted / shiva reddy

DG lube oil Specification is 15W/40
Difference between DG oil and Transformer oil is
DG oil is used for lubricating purpose because in DG Engine
lot of rotating parts are there,
Transormer oil Specification is 40KV and it is mineral oil
we are using oil in transformer for insulating and cooling
purpose

Is This Answer Correct ?    18 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is transient response?

1116


What are the relays in ACB and VCB

2206


by what factor the starting current is used when comparing star and delta connection for motor starting?

2058


How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.

1483


What are the various types of BUSBAR Schemes? explain each

5284


how to avoid Saturation in C.T?

2098


How do we calculate the resistance per metre of single core aluminium stranded cable 19*3.25mm sheathed in pvc,at 15 deg C temperature?

2381


What are the functions of temperature scanner in power transformer?

2167


what is the reactive power what is the use of it in system

2144


what is the breaking capacity and making capacity of circuit breaker and how

2108


How isolater function when installed inelectrical 440V wiring

2203


What is the diffrence (Technical & Construction ) between CBCT & Normal CT?

2005


Advantages of using generator circuit breaker (GCB) scheme in a power station ?

5252


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2135


why output is out of phase in case of common emitter?

2122