WHAT IS THE DG OIL SPECIFICATIONS AND WHAT IS THE
DIFFERENCE BETWEEN THE DG OIL AND TRANSFORMER OIL

Answer Posted / shiva reddy

DG lube oil Specification is 15W/40
Difference between DG oil and Transformer oil is
DG oil is used for lubricating purpose because in DG Engine
lot of rotating parts are there,
Transormer oil Specification is 40KV and it is mineral oil
we are using oil in transformer for insulating and cooling
purpose

Is This Answer Correct ?    18 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is a surge supressor why its is used in synchronous generators

1529


my name is venkat .i have good percentage in my academics(ssc 86, intermediate 83 b.tech 73) my question 1..after completion of my ssc i joined in bpc but i didnt got rank in emcet so i completed MPC in one year compartmentally ..so here what am expect question from this background?

1457


what is meant by the phrase 'static load' in case of shorting in a generator excitation system?

1704


a starter used for squirrel cage induction motor?

1209


What is the unit of magnetic flux density?

701






What is the difference between Delta & Wye windings?

1601


A well system is when , no. of bus bar is less or more. Tell me the concept of it.

1448


What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?

1565


In TNC switch, is there any 1NO+1NC block ? and if we move over closing position, is ther any affect on trip position or vice versa?

1752


Air refrigeration cycle works on the

650


Actually I have a doubt on neutral and earth.we use Ac power without taking neutral by connecting to earth,but at that time does it affects on efficiency of any electrical components or no? If yes how?

949


what are the tests comes under the type test, what tests comes under routine tests.

1025


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1653


What is the function of a neutral reactor.

1310


what is meant by skew width in machines?

1637