Answer Posted / kumaravel
its can be used below rated speed
| Is This Answer Correct ? | 23 Yes | 15 No |
Post New Answer View All Answers
XYZ
why h parameter are called as hybrid parameter?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?
what are the installation procedure of high voltage power transformer,CT,CB&PT?
what happens in the short circuited secondary transformer,if the resistance of the short circuit is increased gradually?
why should small green grass ans small plant should not be there inside the transformer Yard in the factories
i am going to correct power factor of 1600kw induction motor,when i calculate capacitance of capacitor it is three time more in star connection than delta. if motor is star connected which connection i shall adopt for capacitors and reason for adopt this connection
can we install HT panel & LT panel side by side or how much clearance is required ?
hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.
where does 22kv line starts
Single phase and threephase power calculation
when measure the core loss of three phase distribution transformer or three phase reactor loss, one phase shown negative watt loss. why??
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
What is DC series motor?