Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why 4 to 20 ma ,why not 0 to 20 or 3 to 15 or anything

Answer Posted / kambiz

why 4ma show higher zero ?
i have transmiter flow renge 0-1000 m3/h but 4 ma show in
monitoring 200 m3/h and 20 ma show 1000 m3/h i want when 4ma
show 0 m3/h and 20ma 1000m3/h

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Name different parts of a pressure gauge.

1143


send me HPCL paper

10326


What are the application of bernoulli’s theorem?

1159


whats the abbreviation of IOP? is it instrument of power or input open problem?

1174


How process line mpm calculation is done?

1427


How to control flow variations in magnetic flow maters..... When i will provide proper earthing?

2328


If fire would be inside the plant which fire detector is to detected the fire.

1613


How would you choose differential range?

1175


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1954


䑰ҕ䔈ҕ䖠ҕ䘰ҕ䛀ҕ䝐ҕ䟐ҕ䢐ҕ䥐ҕŹ

1955


How to calibrate Field bus transmitter? procedure ?

2356


please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...

1988


Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions? 

2189


pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)

2273


In which principles tx ,pressure gauge,Temp gauge,control valve works?

1829