Can anyone tell me what will happen if AC & DC supply get
mixed???
Answer Posted / vijay kumar surla
The AC voltage is the voltage between the phase and
the neutral. If the neutral is mixed with DC then you can
observe a shift in the AC voltage with the specified dc
line voltage as reference axis. But if the phase is mixed with the DC line then there will short ckt. And the fault current flow through the DC and AC lines.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
what is the significance of tan&delta and how it performed in power transformer
Atwhat condition reverse power relay will act?
What is the role of Dedicated earthing in UPS System?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What is the size of a 60 watt and 80 watt tubelight?
how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.
what is the excess air in furnace
What is center gravity load in substation?
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
what are the problems that generally occur in power flows??
Explain the method to keep noises low in a control system?
how to carried out tan delta test in 11 KV alternator ?
how is capacitor bank look like
What are the special cables required for explosion proof wiring?
What is the formula formula for Busbar sizing and what are the things to be consider for Busbar Calculation?