for 8 mva 33/11 kv transformer what will be the setting of
differential relay on which it trip & what is the HF
setting in this relay
Answer Posted / kanwer
diffferentail rely setting 5% off rated current and hf
setting is 52.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Currently what is the highest capacity (MVA) of SPPg generator available in the market?
what is the benefit of floating our DC source? if i have two floating DC source of which 1 has a ref voltage of -21VDC and the other of -18VDC. can it be connected in parallel to share a common ref voltage? if not, how do i make both sources to be of common ref voltage? tks
what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??
Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????
hello friends.. I have a doubt regarding the operation of dc machines.. I studied in a text book that a dc machine can be used as a generator and as a motor.. is this possible? If so,please send me the info about this topic.. you can also send your info to my mail.
how to calculate transformer turn primary & secondary side 11kv to 420v
Anyone who can recommend an equivalent to Envirotemp FR3 of Cooper?
i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester
What is meant by stator?
anyone knows service engineer in chennai for EDM SPARKING MACHINE.CHMER PULSE CD 60 M.pL GIVE ANY CONTACT NOS
when we have to use UPF wattmeter and LPF wattmeter? what is the difference between UPF and LPF wattmeter in terms of construction?
Whar is the KvA rating of 33Kv substation & actual kv rating of power generaating station.
Enlists the applications of sampled data systems?
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,