What is the Difference between E/P Positioner and I/P
positioner in a control valve? In which applications the
respective positioners are used in?
Answer Posted / s vedpathak
Basically both are same & there is no difference at all
between them.Both are used for controlling C valve. 4-20mA
input to the I/P (E/P) converter converts the current
signal to 3-15 psi which either goes directly to CV
actuator or thro positioner with or without booster(1:1 or
1:2).
| Is This Answer Correct ? | 5 Yes | 8 No |
Post New Answer View All Answers
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
What is difference between “Fault Tolerant” & “Fault avoidance” PLC? Application where these system s are used?
How an rtd work, and what volts/current goes to a rtd to measure the resistance?
What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?
Why all the drains(Gland sealing,ESV,Casing inlet etc) are directly connected to the flash tank instead of hotwell of the condensor in the power plant? My Email Id:naba02222@gmail.com
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
Can any body tell me about SAP MAINTINANCE MODULE. WHAT IS its function and application. And study material Source about it. I shall be very thankful.
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.
while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?
How to calibrate level transmitter with use of HART?
Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose
What is 3 selection available when configure the burnout protection for controller
what would be the minimum flow rate that we can measure on rotameter..?
What are the types of valves?