Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is full form of dyn11( in transformer)

Answer Posted / meenakshi

i agree vid anil...to b more specific,Phase rotation is
always anti-clockwise. (international adopted convention)
we use the hour indicator as the indicating phase
displacement angle. Because there are 12 hours on a clock,
and a circle consists out of 360°, each hour represents
30°.
Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or
360°.
The minute hand is set on 12 o'clock and replaces the line
to neutral voltage (sometimes imaginary) of the HV winding.
This position is always the reference point.
Because rotation is anti-clockwise, 1 = 30° lagging (LV
lags HV with 30°)and 11 = 330° lagging or 30° leading (LV
leads HV with 30°)

Is This Answer Correct ?    7 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to determine Sq.mm size of finolex power cables.

2047


What is genrally the % Impedance of a Dg set? How can we calculate Earthing conductor size for a DG set?

4082


when ID fan will immediately stop through VFD what exactly cause and problem the ID fan

1518


low frequency protection why recomend?

2349


In a 3 phase 4-wire system. For a 3.5 core cable if all loads are single phase and balanced, what will be neutral current? will it be sum of all phase currents? Or it will be zero? And if loads are unbalanced what will be neutral current?

1754


While testing LA mast,What are the parameter limits ?

1957


What is the use for cable entry in control room?

1206


Why mostly the HV side of transformer has Delta?

3273


xpression 'document.FrmQF.myemail' [

2061


r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā

1764


CALCULATE THE TOTAL VOLTAGE DROP AND SELECT THE CABLE SIZE IN MM-SQARE FOR A PANEL-262KW AT 110 METER FROM THE SOURCE SUPPLY , SUPPLY VOLTAGE 240/415

2716


Please explain, how to test vector group of tranformer(Delta y1) . Thank

1751


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1841


working principles of cf lamp,incandescentlamp and f lamp?

2311


What is gross error?

1194