why the under of transformer platform is filled with rock stones.
Answer Posted / rk
TO REDUCE THE FIRE HAZARD DURING OIL LEAKAGE OR OIL
SPILLOVER DURING ANY UTWANTED SITUATIONS FOR INSTANCES SHORT
CKT. INSIDE TRANSFORMER. OIL IS FLAMMABLE IN NATURE.
Is This Answer Correct ? | 21 Yes | 6 No |
Post New Answer View All Answers
What OPGW is better than Microwave or PLCC???
What is a commutator?
What is the main purpose of c.f.b.c.boiler
What is the need of generator relay panel
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
what is DRP panels?
what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?
What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.
why ss stablity limit is more transient stablity limit?
If mutual flux is 1.2wb & power factor is 0.8 lag , then what is the Useful flux of a transformer?
please tell me when we start motor without load in star or delta connection whose current above condition,pl write formula
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
what does mean of RCT and STR in diffrential CT?
What does the kvar means?
What is the universal motor?