Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in the pipe line if the control valve fails to respond to
controller action,by what means we can stop the flow in the
pipe line ?

Answer Posted / karthikeyan

absolutely right answers(1&2)....we can operate in manually,and also to remove the air line because feed water control valve should be a air to open,in this if air fail it should be close....

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is metal of piston ring

1860


Which Signal hart communicator work? If there any signal change when hart connect while transmitter in line ?

1346


What is PDS and PDMS ?

2103


what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...

1960


How to check vortex flow meter is in good condition while we do not having calibration setup?

8762


Senior engineer's please help me, what is Loop Checking and Loop test? and write difference also? soon urgent

2053


Please asked me How calculate DCS controller memory.

2733


How to Calibrate Flow Switch in field

1202


If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

2021


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1612


Calibration of controller (pneumatic)

1907


please send the drdo exam paper

2335


For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

3066


what is the procedure of O2 sensor(ABB) calibration?

2134


Why thermo wells are used? What materials are used in thermo wells?

1064