If we feed 230V ac supply to a full wave rectifare, what &
how much will be the out put voltage?

Answer Posted / rajesh tewari

it is depending upon firing angle of thyristor. how many we
requres in output.we make the thysistor as we need.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain and give me an example of a time when you had to explain some new procedures to your co-workers for quality service delivery, how did you go about it?

1485


when we have to purchase the transformer by own i.e how much load will preferred HT connection?

1189


is the value of inductance depends upon the value of thitha in doubly excited machine??

1557


Explain mechanical rotational system?

625


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

963






how the phase convertor changes the no. of phases

1538


In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.

1120


WHAT IS THE TECHNICAL SPECIFICATION OF C CURVE & D CURVE LEGRAND MAKE MCB

2072


In convertor can we use rectifier thyristor in place of invertor thyristor with explain.

1367


what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)

1666


battery capacity use of made?

2092


What is trip and closing coil in cb? Why need of them

1007


What is the function of the generator exciter?

915


What is Faraday's law

1048


when the time of backcharging the transformer three phases only enough or three phase with neutral is must.from these which one is the best one.

1569