what is the difference between synchronization and paralleling?
Answer Posted / ramireddy
Synchronization is the process of connecting alternator to
the grid system or aiternators which are already connected
parllely.
after it is syncronised to the grid system then it is said
to be working parrlel with another alternators
| Is This Answer Correct ? | 3 Yes | 3 No |
Post New Answer View All Answers
Graphs of measuring power and speed on dc motor
How does zener phenomenon differ from avalanche breakdown?
hwat type of motor is used in thermal gas turbine hydro nuclear power plants and why
How maesure earth neutral value & how much maximum value value required in between earth & neutral.
How is the gain affected by the introduction of feedback in a control system.
what is reverse power relay brief explanation and in b/w where it is connected
Is single load(eg: three phase motor) having all the components like positive,negative,zero sequence components during fault condition?
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
Classify drilling machines.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings
how point on wave controller works.
What is relation between mu(nought) and epsilon(nought)?
What is rotary phase converter?
why we can stote dc? why we cant store ac?