If there is volagte between earth and neutral, what should
be the reason ? and solution
* What should be allowable limit in case, if the voltage
between earth and neutral exist ? / OR what is limit for
safe voltage between earth and neutral?
Answer Posted / saleem
It due to unbalace loads in the three phases.The limitof
voltage between earth and neutral is 2 volts.
To minimize the volt b/n neutral and earth we have to
balance the neutral current.
Neutral current should be minimun.
| Is This Answer Correct ? | 3 Yes | 1 No |
Post New Answer View All Answers
what percent do you derate your copper wire when you change from copper buss to copper wire
What type of wiring series or parallel is used for conventional and addressable type FAS & why?
What is rotary phase converter?
HOW TO CALCULATE THE VT SIZING?
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
pls tell me function of closing coil of A.C.B.
How does "OUT OF STEP" relay ,for Synchronous motor protection, work?
Hello Friends, How can we recognize the CT Star Point is S1 or S2 in case of Electro Mechanical Relays and what is meant by Restraining coil in relays and what is the purpose of that.. thank you in advance..
What is the unit audit? if our Max demand is something and we found much more unit then how to improve our max demand?
i applied for the ap transco please forward the freqventley asked QA
what is high - pot test. what's its use?????
Dyn1 transformer vector group testing how to do
Why field rheostat is kept in minimum position while armature rheostat at maximum position?
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?