i am going to attend ongc exam this coming june for
Graduate Engineer Trainee post
if anybody knows the question pattern or have experience
plz share it with me
Answer Posted / off
Sorry frnzZ.. V cant get the ONGC prev. papers out.. ONGC pple r so strict that they wont even let the exam takers out the questions after the exam.....
| Is This Answer Correct ? | 14 Yes | 1 No |
Post New Answer View All Answers
Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?
How to calibrate H2s Dectector
Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?
What is difference between ESD and PLC please Explain me clearly.
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?
Hook up resistance decade box to temp.transmitter.
What are the interlocks we have to check during the start up of LP/HP compressor?
pls give me presant awerness quistion and answer in my emailid.
where proximity sensor installed on tank in loading arm application
Manipulation of dead wt. tester double piston type.
What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch
a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error
please send the drdo exam paper
can anyone tell me about the basic concepts to consider before to start a PLC panel wiring