Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Difference Between B Curve & C Curve in MCB.

Answer Posted / anil tandon

The MCBs are classified as per the Holding Currents and thus their usage are define accordingly,

B-Curve MCB:- They have a Holding current of 2 times of rated current and are used for Lighting Loads

C-Curve MCB:- They have a Holding current of 5 times of rated current and are used for motoring Loads.

The MCBs are classified as per the Holding Currents and thus their usage are define accordingly,

B-Curve MCB:- They have a Holding current of 2 times of rated current and are used for Lighting Loads

D-Curve MCB:- They have a Holding current of 10 times of rated current and are used for High Inrush currents E.g -Control Transformer etc

Is This Answer Correct ?    47 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz

2291


why capacitive load is not used in routine life????any reason is there ??????

1757


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2127


we have provided 30 nos. relay contacts in panel.I want to know how do we do the numbering for the relay contacts as per any applicable standards

2007


For a stable system, where should the poles of a system be in a root loci plot?

1230


What is the difference between electronic regulator and ordinary electrical rheostat regulator for fans?

1098


hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...

2677


Define average demand?

1342


how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?

1130


how many synchronous motor are there in any power plant

1993


What is the limitation of kirchoffs law?

1124


what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.

1947


What is the Temperature to be set in Thermostat provided in Marshalling box of the Transformer / Motor.

3017


how generator avr give to the input?

1993


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1873