why we use 4-20 mA for calibration of the instruments.why
we cant use 0-20 mA?
Answer Posted / sanjay sojitra
The live-zero represented by 4 mA allows the receiving
instrument to detect some failures of the loop, and also
allows transmitter devices to be powered by the same
current loop (called two-wire transmitters)
| Is This Answer Correct ? | 15 Yes | 2 No |
Post New Answer View All Answers
where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve
I have completed B.E. Instrumentation & control in 2009. i have 3 year industrial job experience in chemical plant.now, I want to join M.E. in external. so, Plese say easiet way and good institute name.
Q- What are the application in which PNP transistor is preferred over NPN ?
define feed forward control loop with example and drawing?
I want to know about DDCMIS in detail ? please explain it. Also give name of reference books in which it is explained in detail in very simple manner.
How digital input and digital output 's are working in dcs
Describe a time when you anticipated potential problems and developed preventive measures.
what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.
Explain the mechanism behind the turbine meter.
what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????
what is controlling card in dcs? how u measure dcs memory?what is bus in dcs?how u know dcs speed n ehternet speed?
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
What is the main difference between Cavitation and Flashing?