Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why rating of alternator in kva & induction motor in kw

Answer Posted / osho katyal

basically we have p=v i cos(phi) The alternator
losses-copper losses depend on voltage and core losses on
current and theres no dependence on power factor.
But in case of motors,the motor is connected to load and
thus power factor comes into role.

Is This Answer Correct ?    5 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.what is the difference between ct and cvt? 2.what is the difference between pt and cvt? 3.what is the difference between relays and circuit breakers?

2737


how to identify the cable quality and what is flame proof cable

2092


i had aplied Hindustan Petroleum corporation limited for the post of maintenance technician -Electrical,i want model questions,if anybody have please send it or please advice?

1856


what is p.s impedance measurement test in earthing transformer?

2390


When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?

1887


What is stepper motor?

1277


Why field rheostat is kept in minimum position while armature rheostat at maximum position?

1091


in 1-phase 230v,how in 3-phase 440v. in each phase in between 230v.

2820


What is resonant peak?

1085


If a rotary UPS is in line through grid power; What would be the impact on Power Factor if the load through rotary ups is 25% , 50% , 75% & 100%. Will the power factor reduce with less load?

1864


why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?

1873


what is the responsibility of C license holder in industry?

9136


what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value

2141


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1858


What is the Basic Difference bitween Long Shunt Connection and Short Shunt Connection in DC Generator?

2330