why rating of alternator in kva & induction motor in kw

Answer Posted / ibrahim

We generate reactive power (within a limit) with help of
changing excitation
for example .8 pf alternator is possible to operate at unity
by changing excitation .8 is the limit to generate reactive
power.if below .8 then we reduce real power only to generate
more reactive power.
But in motor full load it operates at .8 p.f only.......

Is This Answer Correct ?    3 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

4476


i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?

1780


WHAT IS FAULT CAPACITY OF HT MOTOR TERMINAL BLOCK? ANY BODY HAVE ANSWER PLZ....POST IT.

1705


What are the special cables required for explosion proof wiring?

2971


internally connection of photvoltic module

1448






What is the difference between type1 and type2 relay protection co-ordination for motor feeders

1744


Describe the control mechanism of missile launcher???

1515


hai...... tis is Hemanth. jst now completed electrical engineering... i wanna to apper for ap tranco exam... plzz send me the previous q's paper link......thanx in advance.

1579


What is the dc grounding system and what is diff between AC/DC grounding system?

1624


what is the use of current transformer in power transformer secondary side.?its connectyed in WTI

1240


When we need up only in o/p 440v, so why we use directly in 11kva in input?

1270


why the check zone and main zone are used for Busbar Protn. scheem?

1659


i have install 750 kva distribution transformer at my site and want to do neutral earthing. what calculations should i follow to determine earthing conductor material and size?

1572


why we setting 95 deg and 105 deg in wti and oti of distibution transformer ? give the reson for that ?

2572


how can we find thae value of capacitor for single phase motor. what is difference between starting capacitor and running capacitor.

1878