I decided to provide a 11KV / 440V Xformer in my Substaion.
What are the protection required for that?
Answer Posted / rakesh
Transformer Secondary star neutral need to be earthed.
Separate earthing pit need to be provided.
| Is This Answer Correct ? | 3 Yes | 6 No |
Post New Answer View All Answers
what is R Core Transformer. how it differs from normal transformers. dont search in net and post the answer.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
Explain forward resistance, static resistance and dynamic resistance of a pn junction diode.
how to calculate
What is a commutator?
WHAT R THE SAFETIES IN A HIGH TENSION PANEL N LOW TENSION PANEL. ALSO WAT SAFETIES R THERE IN A 200 KVA TRANSFORMER?
On what basis do you decide the ONAN (Oil Natural air natural) or Dry type transformer for a project?
could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?
HOW TO DESIGN THE body EARTH cable(Copper Conductor) size for 60KVA UPS?
What are the basic component of a cro?
Can the output voltage of a rectifier be greater than the input AC voltage without the use of any voltage multiplier in the circuit??please provide the explanation too..
What are the conditions to be satisfied for parallel operation of dc generators?
WHY MOSTLY Rph IS USED FOR CONTROL CIRCUITS AUX. SUPPLY ?
In what cases (circumstances)we should apply P controller, PD controller, PI controller & PID controller ?
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV