Why a starter is used for a motor?
Answer Posted / phani chavali
consider a 3phase induction motor,it is a selfstarting
device.Eventhough it is a selfstarting one we are connecting
this device to starter because if we can not connect this
motor to stator because of sudden flow of currents in the
rotor windings some damage may takes place to the machine.so
we can start up the motor with starter means we can limit
the currents to certain value upto which the rotor gets
accelerated.When ever rotor attained its rated speed then
there is no problem of current flow.
| Is This Answer Correct ? | 24 Yes | 18 No |
Post New Answer View All Answers
how to find the voltage's of a transmission line plzz help with pictures i am not able to understand
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
How to Make relay co ordination chart for a Electrical power distribution of a plant
11000volt DG set carnt kaise banvay
advantages & disadvantages of Lagging and leading power factor .
How cmd is calculated in case of energy neters
What happens if the series current double?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
Suppose a 3 phase, 2 pole, 440V induction motor is driving a flywheel of 600mm diameter, 150kg mass. By using v-belt and pulley, the speed is increased to 4500 RPM. What will be the effect on motor current?
what is the difference between linear choke and suction choke?
state working of halogen lamp?
Explain (in simple ) - root mean square. whats its role in electrical fundamandal.where its used
can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...
what is the correct format to create a resume for interview??
The D.C. spark test is applicable to single conductor cable & assemblies of insulated single conductor cables without insulation shield,metallic sheath or metalic armor?