Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

After synchronization with grid how to maintain the
power factor in lagging or in leading? if lead of lag what
is the problem?

Answer Posted / javad

both lagging and leading p.f will badly affect the system
we have to maintin unity p.f.
lagging and leading p.f will take more current from the
alternator for the same equipment.

eg: power taken by a motor = v*i pf
= 230*20*1= 4600 w
suppose if the p.f is .6 either lagg or lead
in order to get the same power to motor it will take more current ie more than 20 amps.

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

IF DISTANCE IS 100METERS B/W AMP.METER AND CURRENT TRANSFORMER WHAT WILL BE AFFECT IN ACCURACY .METER CAN SHOWING ACCURATE CURRENT OR NOT IF NOT WHAT CAN I DO TO GET 100% ACCURACY.

1832


How can calculate the rating of a alternator for a given specific load with formula

2338


Draw torque - speed curve and load curve of induction motor? mark operating point ?

2041


what is the Pickup/drop off ratio in BCPU relays

4643


How time response of the system is divided?

1186


What is the Designing & Selection Procedure for a DG/Transormer of rated capacity?

2174


what is booster? and how it is connected in a circuit?

2608


How does the slip regulator works as a startor

1960


What do you mean by power transformer?

1066


What is trip and closing coil in cb? Why need of them

1510


In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.

1963


WHY RATING OF VCB NOT LESS THAN 630A

2613


How good are you in resolving the commercial issues to Employer's advantage?

2358


what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?

2251


High voltage test procedure of in swgr board. why should measure millivolt drop on testing time?

2092