Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

After synchronization with grid how to maintain the
power factor in lagging or in leading? if lead of lag what
is the problem?

Answer Posted / m.vasudevan

By using a capacitor bank ppower factor lagging or leading
can be maintained. Leadin power factor is the problem. If
Power factor is leading, the reactive power of total power
export to the grid is high and active power content will
become less.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is meant by bus bar protection?

1103


control & auxilary circuits used for circuir breakers

1840


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1687


we have 3.5MVA-11/6KV transformer. how can we calculate earth fault current and NGR calculation?

1481


Why the magneti fields are not passes from southpole to north pole

2056


why ten delta testing is carried out on power transformer

1766


What is a slack bus?

1084


Star Delta Diagram with full description

2332


describe the A.C. Generator Testing procedure

2116


Why arc quenching is used in Diode ?

2063


What do you mean by turns ratio of instrument transformer?

1032


700KW 6.6KV slip ring induction motor to use VFD to control the speed

3154


what is high and low cut off voltage of BB and DG at SPS????????

1414


How to select a cable size for particular load?

1781


what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.

1831