A rotor of an induction machine is delta connected. Now is
there any necessacity to short the slip rings?
Answer Posted / gurunayk
Its not necessory.....bcz windings already got shorted....
reas star delta starter from B.L.Theraja
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
what is The difference between national electrical code and I.S.Code (electrical) and what is the value of NEC in electrical engineering field
how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters
Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in
What is the effect of positive feedback on stability of the system?
Why we cant store an ac power. If we coo store in which device we can?
I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.
Explain the iniluencc of short circuit ratio on the pert'orniancc of synchronous machine.
Initially, when the input is not equal to the output — what type of response is this?
why the NGR (neutral grounding resistor) always OFF during DG off?
plz send me the syllabus or any sample paper for engineer trainee recruitment if any,on ravinder911@yahoo.com
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?
State magnitude criterion.
Will an earth leakage trip be activated if the component or wiring is faulty on low voltage equipment.Example An electrical Cat Scarer placed in the garden and water gets into the wiring.
EHV current carrying parts need to have smooth finish,then how can a 245kv GIS with emery finish can run so long?