Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

For 300 MW plant what is the distribution voltage

Answer Posted / jagannath swami

Its fully depend upon the switch yard (EB ) how much distance from ur end as per ER 300 MW power gen. upto 220kv S.S. is required . and the distribution is ur hand

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

300m long and 30kw inductive loade 3phase supply how many size cable required

1412


How earthing/grounding done in aeroplanes and ships.

3605


What is Plank's Law?

1137


how to calculate the loss tangent of electrical cables

2056


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2799


We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks

2029


sir pls send the je exam - 2008 and other model question papers..

2056


What is order of the system?

1098


define the non synchoronism of synchoronous machine in general g or m??

1852


what is the difference between b c d curves on mcb

1788


What is making & breaking current ???

1483


Is phenomenon of resonance is harmfull fr the machine? if not or if yes please explain it?

1911


what is Anti-pumping?

1920


delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?

1981


Classify driling machines.

1096