Where the excitation is given either stator or rotor in
actually in power plants?
Answer Posted / ankit
in alternators, we recieve power from
stator side. Now rotor contains
electromagnet to generate poles...so that
rotating magnating field generated by
rotor cuts stator winding.. Hence emf is
generated on stator winding..
Now elecromagnet needs supply to
become magnet.. So excitation is given to
rotor.
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
Can any one know what are the symbols at the down (below) the analog ammeter??? there are 4 symbols which are they ?????
what is mean by D.O. in distribution line poles?
what should be the acceptrd value of winding resistance for 2.5MVA transformer
what is meant by flywheel and its role in retardation test
Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
explain the functions of main isolation switches
Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?
sir my exam is on 19/6/2013 under electrical branch pls send me sample aptitude questions as well as sample technical questions for jindal steel and power company
what is the difference between surge protection capacitor and surge arrestor
I am completed DEEE in tamilnadu, now i am working in andhrapradesh with 2.5 year experience in relavent field. capacity of the tranformer is 11KV, 1MVA Transformer, i am eligible for getting c licence in andhrapradesh pl help me.
if we run a 3 phase machine on two phase what will happend??? given answer with solid reason please
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?
HI SIR, AM PREPARING FOR RRB FOR SECTION ENGINEER POST. PLZ SEND ME THE PREVIOUS QUESTION PAPERS AND HELP ME. I HAVE NO ENOUGH TIME MY EXAM DATE IS 22ND JUNE.... MY EMAIL ID IS nalla.amarnath@gmail.com
sometime battery charged and then automatically charged when rectifier ON conition, is there any chances please clarify the same.