what is the difference between LT and HT power supply?
Answer Posted / chandrasekar
in indian power system
LT supply mean below 440V
HT supply mean above 440V
country vise margin might be upto 1000V
| Is This Answer Correct ? | 71 Yes | 37 No |
Post New Answer View All Answers
how to determine the cable size...pls explain me with the formula taking particular load....does the factors like impedance & short circuit rating influence the cable size, if so how....
what is cascade speed control device?and how this device control the speed of motors?
Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core
In power transmission using open belts or horizontal shafts it is preferable to have the slack side of the belt on the top because
HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????
what is cogging and crawling
Why star delta starter is preferred with induction motor?
What is expention fastener (Fan)
why use phase displacement in transformer.and effect of phase displacement on transformer
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
What will be the voltage regulation of a full load and 0.80 power factor lagging load transformer when a two winding single phase transformer has a voltage regulation of 4.5% at full load and unity power factor?
What are the disadvantages of thermal power plant?
what is the principle of the single phase energy meter? and,what is the advantages and disadvantages of single phase energy meter?