We have laid the single core Armoured cable 7 nos ( 2 each
phase & 1 neutral ) to cater our electrical load .
the issue is though we have Glanded the cable both the end
also givan the earthing to the panel both the end we are
facing a heavy sparking at the gland side. what could be
the reason.

Answer Posted / virendra

Mr sharma Please note that we have a stady system & all the
equipment is properl earthed . there is no such load like
welding machine is existing.Is it cerculating cureent ??????
as this is a single core cable

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will happen if the armature resistance is in minimum position and the field resistance is in maximum position while starting the motor

969


Why human body feel electric shock?

622


Tell me the reason of connecting domestic t/f primary in star or delta,and also secondary side.

1545


define the non synchoronism of synchoronous machine in general g or m??

1440


1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.

2773






how can tell us the AC indoor or outdoor which Tr and formulls

1308


How much minimum insulation required between 11kv/3.3kv transformer windings?

1971


I NEED RRB SYLABUS FOR JE ELECTRICAL ,PLEASE SEND TO MY E- MAIL ID joo28_eee@yahoo.co.in

2392


What are the basic elements used for modeling mechanical rotational system?

612


standard earthing rating for power line..

1665


Why we used 690V in ACS 800 drives.Why dont use standard voltage like 415v or 1.1Kv

1922


how we decide the require size is this for a known current at fuu load?

1430


List some examples of renewable energy?

770


STATE WORKING OF VACCUM CIRCUIT BRAKER?

1465


Batteries. What is the difference between Lead and Nickel batteries ?

1686