Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

howmuch current can carry the 2.5Sqmm copper cable?

Answer Posted / umair

Dear friends,

current rating never depends on length, actually minimum
voltage drop depends on length, the current rating 3 amp
per sq.mm cable so (2.5 sq.mm x 3) = 7.5 Amp

Is This Answer Correct ?    11 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What was your role in the silicon evaluation/product ramp? What tools did you use?

2002


What is the difference between electronic regulator and ordinary electrical rheostat regulator for fans?

1154


we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.

1973


can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value

1920


(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?

2101


In Plumbing services What are accessories we consider for a bathroom?

2050


Explain the different methods used in the choice of rotor slots for reduction of harmonic torques in an induction motor.

2080


Explain how to determine capacitor tolerance codes?

1269


According to conduit size which size wiring & how many wires can we provide wires in conduit & how can we select conduit size accordingly?

1958


two phases with neutral supply can be taken in 3C X 10 sq.mm cable .

1484


which type of questions asking for solar companies?

1633


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1911


What is the minimum underground tank size capacity considered for firefighting purpose?

2006


how do i commission a distribution transformer knowing all its ratings and transformation ratios?d

4665


how is calculated the quantity of weight in hot test xlpe?

2556