Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How Arc Produced in Circuit Breaker When the contacts of the
circuit breaker open.

Answer Posted / mukhesh

yes arc should be produced bcz at last trip contacts
induced curent will beconverted into electro static energy
so that is high voltage so at that time air will act as a
dielectric medium so to form arc if arc to be avoided to
dec deelectric medium so voltage will not rise te ability
to produce arc

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is ignition module of a CAT Gas Genset G-3508 Engine, Alternator SR4B Series. HOw its checked for correct functioning.Is it repiarable or replacable?

2167


How i can calculate current of cable according to ares?

1973


Why the symbol of register is "zig zag"

1572


one conductor length is L.and i am strech uniformly this conductor and made length is 2L.so resistance of this strech conductor is R=4R..but i want to know about area of stech conductor hows it become a/2..

2116


What is the drawback of class b amplifier? How is this minimized?

1113


why a tester wont shock while testing the power in house

1836


What will be the output voltage of a transformer if it is primarily energized from a square wave voltage source?

1079


explain safety measures in alternator?

1760


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1640


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2202


I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)

1872


Explain about how is it working Earth fault'relay and wahts the resistance value of earth bed

1516


Any one can explaination about calibration with rotating sub standards?

2057


How to select transmission line type (i.e. 11kv or 33kv) for new established industries

2018


Define damping ratio.

1223