why we use star connection on the primary side of a
transformer?
Answer Posted / mukhesh
we cant tell always primary is star depend on riqiements
because at genareting station lv side is connected to
station and see side should be star bcz step ujp the
voltage and disubutuin side lv side always seec side is
star bcz it has nutral
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Pl.brief me any electrical major fault you have rectified.
how a.c. genarator control power factor when its conected to grid supply by incrising or decresing excitation voltage.
can anyone send me some sample question regarding power grid corp
How to calculate energy stored in a capacitance
what things to be considered when designing UPS
what are the steps involved in generator load test?
What are the essential characteristics of signal flow graphs?
Sir, I m 3rd year student 4m DCE and want to do internship in siemens or l&t or any other mnc related to electrical engineering. please tell me the procedure 4 same and oblige me
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%
Tell me in detail about c.t. And p.t. ?
please send me RRB electrical engineer previous year questions for Sr. Section Engineer
What is distance between electrical panel to land ?
Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!
What happens if i apply 500V to 440V rotary Switch ?