why capacitor bank always connected in delta,why not in
star to a system?
Answer Posted / kk
Delta connection is parallel effective and star is series
effective. Capacitors offer more impedence when connected
in parallelthan in series.
Is This Answer Correct ? | 114 Yes | 21 No |
Post New Answer View All Answers
How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter
Is there any question in the name of Static Switch in UPS??
List advantges of active filter over passive filter?
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
DIFFERENCE BETWEEN NORMAL TRAFO AND THRISTER TRAFO?
what is package substation.how many types they have
What do you mean by reach and reach the point of the relay?
How to calculate Air conditioning capacity for a telecom BTS shelter?
R=*ΒΆ l/a
In ht capacitor ckt we are using LBS Panel it having isolator with fuse, one of HT fuse flash over, so what is reason behind this event.
sir i used 3 hp of motor for spraying pump, other home light and other home items which size of allminium pvc wire ix used
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
What is the two pole structure?
What do you mean by distribution transformers?
What is marx circuit?