Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between Relay and Contactor

Answer Posted / don

Answer #5 is the best one so far.

I think the question relates only to relays as switching
devices, not protective relays.

A "relay" is a solenoid operated switching device, having
one or more sets of change-over contacts, commonly used to
control (switch) other devices.
The contacts only "break" at one point.

A "contactor" is also a soleniod operated switching device,
but the contacts are discrete NO (normally open) or NC
(normally closed) contacts - not change-over. Contactors
are usually used to switch higher current power circuits
(as opposed to control circuits), such as motors and
lighting.
Contactors usually have three main poles which are fully
rated for its' AC3 rated current, and often a fourth
auxillary contact which is only rated at 10A AC1 - suitable
for control circuits only.
The contacts have a double-break - two points of break.

Is This Answer Correct ?    19 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the reasons of CT circuit faulty in busbar protection scheme?

1419


What is the meaning of C1, C61, C91 cable

3400


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1970


what is class of SPD and dittels of all class ?

2043


what is smartµ grid technology?under coal gassification?

1894


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

8926


1)Explain why the cradle guard is used on railway crossing in overhead line construction?

4985


What happen in ups if phase reverse?

2196


how are reversing the direction of rotation of dc motor

1717


What is Control & Relay Panel? And Remote Control Center?

2174


what will be happen if earth point is being used for as a neutral point for raw power , and same will be used for ups earthing

2016


explain transformer ct connection?

2008


What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

2262


How to calculate phase to phase difference ?

2183


I HAVE A 50A MCCB AS PER DESIGN LINE WIRE CONNECT UPWORD SIDE AND LOAD IS CONNECTED TO DOWNWARD SIDE TO THE MCCB.IF NOW ANY ONE CHANGE SUPPLY & LOAD(WISEVERSA) WHAT HAPPENS ? DOES MCCB OPERATION OR WORKING FUNCTION NORMAL IF YES THAN WHY THERE ARE MARKED LINE & LOAD ON MCCB.

2318