Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I want formula to calculate cable size as per load given in
kw & amp.I searched many sites but didn't right answer.Plz
reply me asap.

Answer Posted / robert nithin

mv= (VD*1000)/L*I

VD= VOLTAGE DROP(AS PER COUNTRY STANDARDS)
L = LENGTH OF CABLE
I = CURRENT RATING
I = P/(1.73*V*PF)
PF= POWER FACTOR
MV= MILLI VOLTAGE DROP/AMP/METER

SELECT THE CABLE DEPENDING UPON THE MV RATING IN PRODUCT CATALOGS

Is This Answer Correct ?    121 Yes 60 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why is it prefer to initiate circuit breaker failure by "86" lockout relay not by "94" tripping relay ?!

1804


What will be the output voltage of a transformer if it is primarily energized from a square wave voltage source?

1103


How to calculate cable rating for 3 phase supply?

2189


What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance

2003


how does high earth to neutral voltage affect electronic equipment?

1557


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1593


(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?

2047


how to calculate the no load current in transformer?

2524


describe the Operation of induction generators from bus bars

2325


What is pole of the system?

1151


I COMPLITED MY B.TECH AND 10TH CLASS WITH 70%MARKS BUT 12TH CLASS 55%MARKS..CAN I GET INDIAN RAILWAY RECUREMENT EXAMINATION?

2188


What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act

2038


which is chemical used as in ro water what is difference betweeen multi grade filter&dual media filter

2120


How to measure size of cable on a given load

1840


what is the use of sdf?

2103