Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is relation of rpm with Power supply? rpm directly
Proposational to power ?

Answer Posted / k.l.subrahmanyam (nb ventures)

mechanical o/p=(2*3.14*n*t)/60 ,mechanical i/p of a generator = electrical o/p (if loss is negligible), then (2*3.14*n*t)/60=v*i (concider o/p is dc ),speed(n) increases mec o/p increases there fore generator i/p also increases,o/p of generator is v*i (emf=n*(d pi/dt),emf=v) due to increase in speed the voltage also increases there electrical o/p also increases

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is load vs Torque curve & why it is used?

2052


We are planning to synchronized DG's with our captive plant in the event of black start of plant, but before sync we checked voltage of DG with our plant voltage and it varies from 5 V to 450 V. So in this condition how we can sync DG with plant ?

1627


how to calculate slip ring induction motor stator and rotor currents??

2248


Single phase and threephase power calculation

2125


How to decide and select the different earthing wire size for the different types of earthing

2255


How you calculating the 30 Hp 3 phase AC motor of power what size of cable is used for this motor?

1643


Electrical 'C' license full abbreviation , and full form

1866


How to know any size of cable if there are not written on cable? Answer must be theurical not by experience.

2107


What is different bewteen low or high impedance busbar protection scheme

4102


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1762


what is R Core Transformer. how it differs from normal transformers. dont search in net and post the answer.

2066


What is a advantage of Self Reset Lockout ? On Fault breaker get trip & fault no longer exist then self reset lockout how inform us?

1853


how to carried out DAR test in 11 KV Alternator ?

2276


wHAT IS CAPACITANCE LATCHING? hOW TO CALCULATE CAPACITANCE LATCHING? hOW TO SOLVE THE PROBLEM IF CAPACITANCE LATCHING APPLIED?

1989


can i connect the two phases of scott connected transformer,if not why?

1956