what is relation of rpm with Power supply? rpm directly
Proposational to power ?
Answer Posted / k.l.subrahmanyam (nb ventures)
mechanical o/p=(2*3.14*n*t)/60 ,mechanical i/p of a generator = electrical o/p (if loss is negligible), then (2*3.14*n*t)/60=v*i (concider o/p is dc ),speed(n) increases mec o/p increases there fore generator i/p also increases,o/p of generator is v*i (emf=n*(d pi/dt),emf=v) due to increase in speed the voltage also increases there electrical o/p also increases
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What is the Designing & Selection Procedure for a DG/Transormer of rated capacity?
Please define ohm’s law for a.c (alternating current)?
Which cable is use for rtcc control panel
if 2 coil of 1000W connect in series and 200 v is applied across it . then what is the total power of coil when coil have only resistive load .
how the works electronic energy meter?
Define piezo-electric effect?
What is meant by turbo alternators?
How to control motor gearbox speed and friquency? If length of cable and dia given, how to measure the voltage drop?
current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer
how to select energy meter? have any calculation?
HI SIR, AM PREPARING FOR RRB FOR SECTION ENGINEER POST. PLZ SEND ME THE PREVIOUS QUESTION PAPERS AND HELP ME. I HAVE NO ENOUGH TIME MY EXAM DATE IS 22ND JUNE.... MY EMAIL ID IS nalla.amarnath@gmail.com
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
HOW CAN YOU CALCULATE PRACTICAL EFFICIENCY OF A ASYNCHRONOUS INDUCTIONMOTOR OF 7.5KW,& MOTOR IS RUNNING WITH AVOLTAGE OF 410 VOLTS,& TAKING CURENT OF 13 AMPS
how works inductive &capacitive sensors?
IN electrical field, WHAT ALL THINGS THE CUSTOMER WILL ASK WHILE ORDERING FOR LT PANEL (ALL TYPES OF LOW TENSION PANEL)