what is the highest transmission voltage in India till now?
Answer Posted / sunil
765kv
| Is This Answer Correct ? | 17 Yes | 1 No |
Post New Answer View All Answers
At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?
Why frequency changes due to load variation in power system ? i.e why when load increases frequency decreases?
we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor
1.ZEBRA conductor(large size) 2.KUNDHA conductor( small size ) 3.panther conductor(very small ) 4.lepard conductor (very very small)
How to Preparation of online test
Wt is the function of reactive power? How it generates & consume though resultant is zero?
WHAT IS THE USE OF PIG TAIL IN WINDOW CT ?
What is the lower limit of break-down voltage of converter transformer.
Define unilateral circuit?
In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
solar inverters was not connected to the nuteral link .this nutwral possible to any other systems
In hydel power plants, L.A's, S.C's are placed inside the control panel boards. what is the purpose? [already the total body was earthed to ground.]
Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?
Why let through energy not considered for ACB breaker while cable sizing?