While testing the 33KV Busbar by using Hipot kit, what
should be the test
voltage we have to apply?
Answer Posted / prabhas
You should apply the voltage step by step till the double
voltage capacity of the cable. this is during only in the
1st time of test for 2nd time onwards 1.8% is preferble.
Ex:33KV: You apply till 65KV
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
What is the significance of integral controller and derivative controller in a pid controller?
-What shall be short circuit current of LV switchgear for a 1000 kva, 11.415kv, 3 phase tranformer with 5% reactance.
How to calculate the phase to phase clearness of HT /// LT bus bar?????
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
what does a string of resistors in a series will do?
I want formula to calculate current loss with distance in km.I searched many sites but didn't right answer.Plz reply me
diff b/w elcb and rccb
Why r u using pf panel. what the uses
What is the source of dependent source ?
What Should be the value of Vector Surge angle at Tripping and how to calculate it?
what is the function of gss in the dg set.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
sir please send me previous year questions of jspl of electrical section through which i could prepare myself fpr the test.
A low wet bulb temperature indicates
Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC