what is the working principle of vortex flowmeter
Answer Posted / muhammad imran
dear friend,
in vortex flometer, it is natural phenomenon that if you
put an obstructionin the path of flow, automaticaly vortex
are generated.in this case the important point to be
observed is that the number of vortexes generated are
directly propotional to the velocity of the flowing fluid
but the distance between vortex to vortex remain constant,
while we have the formula
v=F.lemda..... where the lemda is defiened as the distance
between vortexes which is constant.
and velocity is directly propotional to frequency.
where we can use several types of sensors to detect the
vortexes, such as piezo electric type sensor. when a
vortex will hit to the sensor the pulse is generated and by
calculating the number of pulces we can determine the
velocity and then flow.
YOU can physically observe this case.. ... but it is to be
needed to go near river and search the place where the
stones are up than water level. sit there and observe the
phenomenon
it is better to fo that place where the depth of water is
not more than 6 inch and flowing speed is not much fast
...... cisit that place daily and observe that when the
flowing speed is more that day the more vortexes are
generated
| Is This Answer Correct ? | 44 Yes | 1 No |
Post New Answer View All Answers
HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?
What is the start up procedure of desalter
What are the maximum packet size of: a) HART b) Profibus DP c)Profibus PA d) DeviceNet e) Foundation Fieldbus
Explain the working of an enraf level gauge.
Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...
What is zone,loop/fire alarm system?
how to tune siemens sipart electro pneumatic positioner..plz tel me..
What is the GK Value in Flowmeter?
Explain operation of Haskel pump.
Why plc require in analog input 4-20amp & 0-10 volt?
what is performance test.need defination
in mass flow meter what is drive friquancy ?
In VVVF DRIVES VOLTAGE IS ALSO VARY WITH THE FREQUENCY. HOW? WHAT IS THE DIRECT FORMULA RELATING THESE TWO.
how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)
how to rectify the poor signal strength in utrasonic digtial flow meter ,model:ge digital xce868i