Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in ac system the current wave form becomes zero for every
half cycle then how can we get continuous supply can any
one answer to this plsss

Answer Posted / guest

For a 50 Hz AC system,the voltage or current waveforms
becomes zero after each time intervals of 10 ms(Time period
is 20 ms).

Mathematically, the sinusoidal function is a continuous
function.

Strictly speaking, we do get zero instantaneous values.The
instruments(ammeter,voltmeter),on whose basis the claim of
disconiniuty of supply is argued,measures either average or
rms value which is certainly not zero.

If the CRO is used to see the waveforms it will show
perfactly sinusoidal which has zero as well as other
values.So where is the question of not getting zero values?

If the bulb or lamp is chosen to checking the
continuity,its glow depend upon the rms value,not on the
instantaneous value.So we get continous glow as a
indication of continous supply.But in actual,the waveform
had gone through the zero value also which was not evident
from glow.

Author:arbelectbit@yahoo.com

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends

2801


PLZ EXPLAIN THE INTERLOCKING AND CONTROLLING OF CONTACTORS????HOW CAN I DO THAT?

6724


With a phasor diagram show the effect of increasing the field current of a generator supplying a constant real power and connected to a grid system.

1905


Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?

1863


How can get elongation of 2 k.G aluminium, if elongated aluminium dia is 2.5 mm?

2248


We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.

1820


What are dependent sources?

1106


What is the effect of pi controller on the system performance?

1061


what is the meaning of number in (11, 31, 61,14, etc. CDG11, CDG31, CDG61, DDT32

1373


what is the Transformer Impedence?How can calculate?

2023


why we cannot protect 100% winding of an alternator by using differential protection?

2203


what is the difference between neutral and earth

2011


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1972


differnce between single acting and double acting solenoid valves

1787


how we test a 3 phase motor on single phase supply....? HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for testing..? how we verify of a 3 phase motors 6 wire & name thame a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta starter ........i have only 1 phase supply ? help forum..........

5084