Answer Posted / p. h. godavary
Here the question is not correct. Transformer ratings are never in multiples of 11.
It is the Generator voltages that are in multiples of Form factor 1.1(approx.). The voltages are 3300V, 6600V, 11000V. Consequently the normal distribution / transmitting voltages used are 3.3KV, 6.6KV, 11KV, 33KV, 66KV 110KV, .......
Form factor of an alternating current waveform is the ratio of the RMS (Root Mean Square) value to the Average Value of the waveform]. In the case of a sinusoidal wave i.e. , an analogue wave, the form factor is approximately 1.11
| Is This Answer Correct ? | 34 Yes | 3 No |
Post New Answer View All Answers
how can we phase identification in a distribution line,how we recognise that which phase is coming for a house hold connection.help me............
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
What are :- AC Distribution Board (Single & Double Front) DC Distribution Boards Distribution Board LT Breaker Panel.
what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor
LT cable fault chaecking equipment and to find out the distance at what distence it failure . Name and where it is available?
Why reactors use before incoming of ac vvfd drive?
how does the rotating m.m.f is produced in the 3-phase induction motor and how the poles are created in 3-phase induction motor ?
Explain difference between stand by earth fault and residual earth fault protection?
salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
What is the effect on Power factor and capacitor when your company load is more than 70 % of welding transformer
what is v/f control in VFD?
what will happen if there is a voltage leakage or current leakage in an electrical train
What is the vector group of a transformer,how can it be found out?
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?