Is there any difference between load based power plant and
coal based power plant?
Answer Posted / iamdon
Yes.
Coal based power palnt is established at the site of coal
centres(mines).Modern trend is of coal based power plant.
Since now we are well advanced in electrical technology and
also we dont want to be affected with transportaion
problem.So the choice is obvious.
Load based power plants are established at the load centres
(industries).This was earlier choice of thermal power
plants so as to reduce transmission cost as we were in
intial stage of technology.The major difficuly with load
based power plant was frequent transportation problem.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
What are the weight of 800KV DA,DB and DC type tower ?
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
What is the safety of UPS?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is the internal working of star delta starter
How do we calculate transformer oil in liter from the rating of the transformer.
75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?
how is the magnetic current test is different in delta-star and delta delta transformer.
What is called grain-oriented laminations?
List examples of current sources?
How to calculate the size of earth cable to earth the neutral of UPS ?
what is ramping rate of generator
Difference between Earthing Truck & Earthing trolly for HT panel
Cb closed condition if there is a tcs fail whether cb will trip or not