Answer Posted / iamdon
At no load the speed of IM is VERY CLOSE TO SYNCHRONOUS
SPEED but not equal to synchronous speed.
As the mechanical load on the motor shaft is increased,the
motor slow down.Due to which the relative motion between
rotating magnetic field and rotor conductor increases.Thus
more emf will induce in rotor conductor according to
Faraday's laws.Since rotor conductors are short circuited
so more current is induced according to Lenz law.The
induced current will flow through rotor conductor causing
more electromechanical torque to be developed.In this way
motor meets the increased load demand.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
XYZ
hello friend i wish to study a course related to the electrical construction, controlling and monitoring , which course i want to study? pls give me the name of institute?
In case of HV test on medium voltage cables, BS is asking for 4 U0 where as IEC is asking for 3.5 U0. Can any one advise me how this 3.5 times or 4 times U0 is derived?
I am EEE student i want to improve my core side skills.how cn i approach it?
what is the IS foe lightning arrester?
Which motor will you choose which can operate in both lagging as well as leading power factors?
why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.
What is meant by stator? What is meant by rotor?
what is the synchronous timer ? and it applications.
what is the voltage between earth to neutral in lift.
How do i right a ladder diagram that has 1 actuator that performs a full stroke followed by a half stroke
What is pole of the system?
substation+ plc system
hi this is hema can anyone mail me previous years questions for the APPSC-A.E.E (in electrical stream.) ......thank u.
What are the basic component of a cro?