WHAT IS THE DIFFERENCE BETWEEN PLC AND DCS
Answer Posted / samir kumar sanyal
Plc is a part of DCS in which plc control only the
equipments which are operate by on off system but DCS can
control those equipments and process variables very
accurately. That's why DCS is used for very big and
sophistricate plant.
| Is This Answer Correct ? | 4 Yes | 5 No |
Post New Answer View All Answers
Why upper weighing limit of electronics balance is 90% of the total weighing capacity?
Reason for capillary type dp level transmitter fluctuation
how u calibrate sox nox co2 co in cemps?what is opacity n HPm?tell the standard parameters of cems?
how to calculate signal cable sizing? and multipair cable sizing??explain in brief?
typical loop drawing of a simple feedback control comprising of one transmitter and one control
How does a single acting, spring return ball valve actually work? Does it require continuous air supply?
What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch
please send the drdo exam paper
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
What is zone,loop/fire alarm system?
Explain the difference between plc and cnc?
Can anybody tell me how to select the size of earthing cable for DCS & PLC system.Please tell me any relevant answer here or mail it to me.
how to tune siemens sipart electro pneumatic positioner..plz tel me..
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
Explain the use of hair spring in the pressure gauge.