Answer Posted / newsearchone
Dear Sir,
Our next batch start from 23rd Jan 2010.
Regardind SPI training following are deatails
(I) SmartPlant Instrumentation (Version 7.0) for Users:
This course is designed for instrumentation specialists
involved in the definition and specification of
instrumentation and control systems using the SmartPlant
Instrumentation software. In this course, students learn
how to define the instruments using SmartPlant
Instrumentation as per the
specifications of project deliverable.
Topics Covered:
1.System and Project Administration Overview
2.Instrument Index
3.Process Data
4.Calculations
5.Specifications
6.Wiring
7.Loop Diagrams
8.Hookups
Course duration is 15 days
Fees is only 40k + accommodation .
Address:
Room No B-101,Sector-11, Sidivinayak housing society,
Kharghar,Navi Mumbai.
Mob no: +91-9975796100
Regards,
Paresh Patil
| Is This Answer Correct ? | 3 Yes | 4 No |
Post New Answer View All Answers
i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com
how to turbine speed measurement?
what is exact time to study dcs and plc cources
Q1]IF THE RANGE FOR FLOW IS -35 TO 125 WHAT WILL BE THE SPAN FOR ABSOLUTE AND FOR NORMAL? Q2]HOW TO CALIBRATE CAPILLARY TYPE LT? Q3]HOW MANY ERROR CALCULATIONS ARE THERE USED IN PROCESS INDUSTRIES? Q4]HOW TO CALIBRATE TEMPERATURE TRANSMITTER? Q5] HOW TO CALIBRATE LEVEL TROLL AND HOW TO CONNECT? Q6]PLEASE TELL ME THE BASIC FOR INSTRUMENTATION WHICH IS APPLIED FOR CALIBRATION AND FOR ALL? PLEASE MAIL THE ANSWER TO honest_yes@yahoo.in
on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon
what is function of switch, and how is it work, explain with difination
Can Any body tell me how to check Modbus Settings in ER300N L&T trivector meter?
What is the start up procedure of desalter
Tell me the field calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter.
what is the input to be given in digital flow meter during the the calibration time?
Explain bernoulli’s theorem.
what can of fault ofently come in vibration mesurement?
In most instances, Inertia processes are quite uncommon. Give an example of a combined Resistance and Capacitance situation.Describe an application, which according to your understanding of the subject matter, comprises of both Resistance and Capacitance effects.
please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.