Which is stiffer between salient pole rotor and cylindrical
rotor synchronous machines? Justify your answer.
Answer Posted / iamdon
Salient pole rotor synchronous machines are stiffer as
explained below.
By stiffness of synchronous machines,we mean that the
amount of synchronising power(Ps)avaliable, for machines at
a particular operating point, to bring back the machine to
synchronism when the machine is subjected to disturbances.
Mathematically,
Ps=derivative of electrical power(Pe) with respect to load
angle(d).
In case of salient pole synchronous machines, Pe contain
two powers added together
1)The reluctane power and
2)(E*V/X)sin d.
Also due to large air gap, reluctane offered to armature mmf is
more.So there is less armature reaction effect which in turn
reduces the value of synchronous reactance.
In case of cylindrical synchronous machines, Pe contain
only
1)(E*V/X)sin d term.
So Ps is greater in salient pole synchronous machine as
compared to cylindrical rotor synchronous machine.
Author:arbelectbit@yahoo.com
Is This Answer Correct ? | 18 Yes | 4 No |
Post New Answer View All Answers
Explain the laying procedure and laying depth of submarine/subsea power cable for 220/400KV system? Also available cable diameter?
previous year paper of ntpc bhel for degree in electrical enng
How to megger test 11 kV cable and the acceptance IR value
How seriving & testing of the HT & LT breakers are done. What are the standard Ir values on which we can come to know the test is passed or failed?
describe the A.C. Generator Testing procedure
thyristor controlled APFC panel design parameter?
Can we use shunt trip coil instead of trip coil with protection relay for protection?
Why we use circular(Stepped) cross section in transformer core?
Explain cmrr?
how line turns ratio changes in 3 phase with change in connection
hi plz send me reliance placement papers..i.e electrical technical papers that have been asked in reliance test.
What is the permissible maximum flux density in transformer core?
How to see the inductance in a transmission lines
how to select the mpcbs and contactor for 3 phase 30 hp star delta motors.for plc control.and tell me the calaculation for future use.
what is the difference between linear choke and suction choke?