Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the working of ups.

Answer Posted / sunil guru

BASIC USE AND RUNNING OF UPS IS WRITTEN ABOVE ....
LET ME GIVE SM DETAIL EXPLANATION

UN-INTERRUPTIBLE POWER SUPPLY(UPS)---- HAS BASIC 6 CIRCUITS FOR ITS COMPLETE WORKING

1> MAINS UNDER AND OVER VOLTAGE CUT-OFF CIRCUIT
2> BATTERY CHARGER CIRCUIT
3> RELAY CHANGE OVER CIRCUIT(FROM MAIN TO BATTERY MODE-IN ABSENCE OF UTILITY)
4> BATTERY DEEP CUT OUT CIRCUIT (AT LOW BATTERY THIS CKT WILL CUT OFF BATTERY FROM CKT)
5> INVERTER CONTROL CIRCUT (CONVERTS FROM DC TO AC)
6> POWER OUTPUT STAGE (WITH THE HELP OF TIMER(555),TRANSISTOR AS A SWITCH AND USING MOSFET OR IGBT WITH APPROPRIATE DRIVER TO SWING DIRECT CURRENT TO ALTERNATING AT 180 DEGREE PHASE DIFFERENCE AND PRODUCING 50 HZ FREQ WE CAN DELIVER THE 220 V AC POWER

FOR ANY DISAGREEMENT OR MORE IMFO CONTACT ME ON PARMAR20072008@YAHOO.COM

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

My load is 1635 KW. & current pf is 0.884, I have to improve it for 0.99.Please suggest what KVAR value is needed?

1551


what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??

9393


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2421


Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?

2291


How much costly in percentage wise is sandwich busduct costly than air insulated busduct of any rating?

1733


what do you mean by class PS CT and what are technical details needed for calculating it?

1944


How to calculate the Efficiency of Chiller

3282


what is droop control?

2095


r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā

1667


How to design the NGR Resistance

2017


hi frnds...pls send me aptransco previous papers .....pls..pls,,,(madhar.rocking@gmail.com)and suggest me some websites

2082


What is the function of auadag in a cro?

1069


write a c++ code that receives an integer number and display the sum of the number and its revers integer?

1984


what are the advantage and dis-advantage of 3 phase 4 wire energy meter?

2138


Can we convert off line transformer to on line transformer

1934