Answer Posted / sunil guru
BASIC USE AND RUNNING OF UPS IS WRITTEN ABOVE ....
LET ME GIVE SM DETAIL EXPLANATION
UN-INTERRUPTIBLE POWER SUPPLY(UPS)---- HAS BASIC 6 CIRCUITS FOR ITS COMPLETE WORKING
1> MAINS UNDER AND OVER VOLTAGE CUT-OFF CIRCUIT
2> BATTERY CHARGER CIRCUIT
3> RELAY CHANGE OVER CIRCUIT(FROM MAIN TO BATTERY MODE-IN ABSENCE OF UTILITY)
4> BATTERY DEEP CUT OUT CIRCUIT (AT LOW BATTERY THIS CKT WILL CUT OFF BATTERY FROM CKT)
5> INVERTER CONTROL CIRCUT (CONVERTS FROM DC TO AC)
6> POWER OUTPUT STAGE (WITH THE HELP OF TIMER(555),TRANSISTOR AS A SWITCH AND USING MOSFET OR IGBT WITH APPROPRIATE DRIVER TO SWING DIRECT CURRENT TO ALTERNATING AT 180 DEGREE PHASE DIFFERENCE AND PRODUCING 50 HZ FREQ WE CAN DELIVER THE 220 V AC POWER
FOR ANY DISAGREEMENT OR MORE IMFO CONTACT ME ON PARMAR20072008@YAHOO.COM
Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
Match the following a)(X'+Y') b)X'Y' C)XY 1)NAND 2)NOR 3)Carry
What are the disadvantages of thermal power plant?
Discuss the effect of sudden loading of an induction motor
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
what will happen if frequency is below 50 hz?
What is center gravity load in substation?
why ups rating in kva? and why ups are in parellel?.why isolation transformer is used in ups?
Explain what is use of lockout relay in ht voltage?
advantage of motor design on higher power factor . normally motors are designed for .8 power factor. what is advantage of designing at .88 power factor
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?
how many types are their in switchyard or substation(like D,I TYPE), what is differant between them
What is meant by cold loop test in instrument
High speed earth switch operation with diagram
What is the safety of UPS?