Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the safety protection? Name the protections of
Transformer?

Answer Posted / p.r.gowri sankar

The "Safety protections of the Transformers" are fallows
1.Neutral Earthing
2.Bucholtz Relay
3.over Current Earth fault Relay
4.Differential Voltage Relay
5.Instantaneous Voltage Relay
6.Earth Leakage Relay

Is This Answer Correct ?    12 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Transmission through a short line depends on

2255


what happens if dc supply is given and the remedies for it.

1810


how commomn gate triggering is given for TRIAC ? other thyristor wont be efffected?

2427


Is there any standard guidelines/Criteria to design NGR/NGT.?

2837


i have interview in Pepsi company what type of question will ask please send the question and answeer

3448


1.ZEBRA conductor(large size) 2.KUNDHA conductor( small size ) 3.panther conductor(very small ) 4.lepard conductor (very very small)

2910


the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?

2264


What will be the diameter of pipe between conservation tank and transformer

1923


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1449


What is the minimum distance to be maintained in between HT panel and LT panel and Instrument panel as per IEC and NEC standards?

1722


with out colour codeing on conductor how can be find what is r,what is b,what is y phases.....

1944


State angle criterion.

1113


What are the common sources of energy?

1088


What is a difference between indoor transformer and outdoor transformer of same rating

5814


WHAT IS VCB SAFETY

1249