How we can convert H.P into KW or Vice versa
Answer Posted / nookaraju
one HP = 746 ,watts equal to 0.75 kw, equal to 3/4 kw. so, HP to KW is 3/4 and KW to HP is 4/3. Then we get ans.
| Is This Answer Correct ? | 3 Yes | 3 No |
Post New Answer View All Answers
my bachelors was done with EEE now i got admit in NU with CS as course. how to answer this qns 1) why u choose cs? 2) why u changed from eee to cs
How harmonic block test are conducted on relays ( Siemens,Areva ect )power transformer using omicron kit?
WHAT IS IEC? & WHAT IS BENEFIT TO PRODUCT FROM IEC?
what is earth fault relay 64T, why it is used in main Incomer and neutral CT of Transformer.
what is mean by NPS (Negative phase sequence)fault? what is the difference between EFR & OCR faults?
how can found motors folt current ? how can disided circuit breakers caoicity and breaking capicity ?
why star point of HT motor not earthed?
Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?
What are IR values and what it should be for coil and for insulator
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
what is the standard duration after failure EB power
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
how to calculate energy of 3-phase motor?
r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā
What do you understand by oldham's coupling ?