Answer Posted / benchalli nagaraj
LT:MEANS LOW TENSION ITS RELATED TO VOLTAGE
THERE ARE THREE
1) LOW VOLTAGE (0 TO 415V)
2) MEDIUM VOLTAGE ( 415 TO 690V)
3) HIGH VOLTAGE ( ABOVE 690V,11000 LIKE)
Is This Answer Correct ? | 4 Yes | 4 No |
Post New Answer View All Answers
Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station
hi can anyone pls tell me the eee interview core questions asked in l&t
What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?
what is difference between earthingpits,earthing grid & earthing mess?
WHAT IS START TO INDUCTION MOTER IN STAR TO DELTA OF >5HP ?
Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.
placing earthing pit in pathway is correct or wrong??. placing earthing wireGI1/18 inside walls is correct or wrong?. explain!!!
If more than rated DC voltage appears across trip coil of the breaker, what will happen? e.g. in 110V DC circuit system, if voltage across battery terminal showing 121 V
DEFINE BREAKING CAPACITY OF BUSBAR & HOW IT IS CALCULATED?
if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.
WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?
what is the use of static frequency converter and static excitation equipment? and where it is employed? for what?
hi guys please tell me the procedure for mesuring the coil resistance of 3ph induction motor?
What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?
Currently what is the highest capacity (MVA) of SPPg generator available in the market?