What are the factors to be considered during the
Synchronization?
Answer Posted / anurag sankar sengupta
the following factors are very much important in case of doing synchronization.....:
1> the incoming and running alternator should have same operating frequency.
2> the output characteristic of prime mover should be same for both the alternater.
3>they should have the capability to produce same type of output... ie.sine wave waveform.
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
What do you mean by ratio correction factor of instrument transformer?
What Normal(Tangent) towers and Tension(Cut-point) Towers?
What is the method of estamating of cable, CB,MCB ?
How will polarity test of Dy5 Transformer ?
What is Auto Mains Failure Panel & Auto Synchronizing Panel
what shoud be strength and weakness to impress interviewer????????
formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?
current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
We have 110Vac ,10A ac supply which is converted into 110VDC & How much DC current? which factor is reqired for dc current calulation?
What is the need for a controller?
what precautions to be taken while desigining a LT,HT panel. Eg-LT panel PCC panel with ACB installed. HT panel VCB panel with VCB installed. & what is main diffrence betwn IP54 & IP55 construction of panel.
how many types control panel of a 132/33 kv substation
Merits & Demarits of Oil circuit & Air circuit breakers ?